model pfe300 pfe700 pfe500f items pfe500 (preliminary) ac input vac 85 to 265vac, 47-63hz (operation to 440hz possible(3)) input current (100 / 220vac) a 4.0 / 2.0 8.8 / 4.4 6.8 / 3.4 model dependant 6.2 / 3.2 inrush current (100 /200vac) (1) a 20 / 40 peak power factor 0.95 minimum output voltage setpoint accuracy - 2% 1v 2% ripple and noise (1) - 1% 4v 1% over current protection % 105 - 140% (automatic recovery) over voltage protection - 125 - 145% 60 - 69.6v 125 - 145% series operation - yes parallel operation - no yes (droop mode) yes (single wire) power on signal (ena) - open collector (10ma sink current). low (on) when output is present auxilliary supply - none none 10 - 14v, 20ma remote on/off (opto isolated) - none none high = on overtemperature protection yes operating baseplate temp. c -40 to +100c (2) storage temperature c -40 to +100c humidity (non condensing) operating: 20 - 95%rh, non operating: 10 - 95%rh cooling conduction withstand voltage input to output 3kvac, input to baseplate 2.5kvac, output to baseplate 1.5kvdc isolation resistance output to baseplate: 100m ohm at 500vdc, 25c ambient, 70%rh vibration (non operating) 10-55hz (1 min sweep), constant amplitude 0.825mm (max 49m/s 2 ), x, y, z 1 hour each shock 196.1m/s 2 safety certifications ul60950-1, csa60950-1 (cul), en60950-1, ce mark (lvd) weight g 250 250 300 size (wxhxl) mm 61 x 12.7 x 116.8mm 70 x 12.7 x 122mm in 2.4 x 0.5 x 4.6? 2.76 x 0.5 x 4.8? warranty yrs 2 years pfe300-700 3055 del sol blvd ? san diego, ca 92154 ? 1-800-lambda-4 ? low profile ? assists system integration ? high efficiency ? easier to cool ? power factor corrected (pfc) ? supports global use ? operation up to 100c baseplate ? operates in harsh environments feature benefit ? low profile, small size ? 100c baseplate temperature ? high power density ? high efficiency ? suitable for conduction cooling 61 features and benefits specifications 300 to 714w ac-dc power module notes: (consult installation manual for detailed specifications, test methods and application notes) 1) external components are required, consult application notes 2) PFE500-12 & pfe500f-12: -40 to 85c. see instruction manuals for derating curves 3) requires the use of an undervoltage relay or similar. contact technical support
pfe300-700 3055 del sol blvd ? san diego, ca 92154 ? 1-800-lambda-4 62 pae, pah, paf 50 to 600w dc-dc converters cc-e, px 1.5 to 40w dc-dc converters other lambda products pfe500 basic connection pfe500 and pfe700 outline drawing pfe500f outline drawing revision b3: mar 2008 for additional information, please visit www.lambdapower.com/products/pfe-series.htm haf-10l 116.8 x 25.4 x 61 2.2c/w haf-15l 116.8 x 38.1 x 61 1.9c/w haf-15t 116.8 x 38.1 x 61 1.5c/w heatsink size (mm) thermal resistance heatsink table blank m3 tapped mounting inserts (4) /t 3.3mm non-threaded inserts (4) suffix description options pfe300-12 12 9.6 - 14.4 25 300 48 48 81 / 83 PFE500-12 12 9.6 - 14.4 33 396 48 48 82 / 83 pfe500f-12 12 9.6 - 14.4 42 504 48 48 81 / 83 pfe300-28 28 22.4 - 33.6 10.8 302 56 56 83 / 85 pfe500-28 28 22.4 - 33.6 18 504 56 56 84 / 86 pfe500f-28 28 22.4 - 33.6 18 504 56 56 84 / 86 pfe300-48 48 38.4 - 57.6 6.3 302 96 96 84 / 86 pfe500-48 48 38.4 - 57.6 10.5 504 96 96 84 / 86 pfe500f-48 48 38.4 - 57.6 10.5 504 96 96 84 / 86 pfe700-48 51 none 14 714 50 - 57v (5) 86 / 89 (4) 100 / 200vac (5) total regulation range output adjust. maximum maximum load line efficiency model voltage (v) range (v) current (a) wattage (w) reg. (mv) reg. (mv) typ (4) model selector
|